From: Investigating the utility of a high-temperature Thellier-style paleointensity experimental protocol
Flow | Teanby et al. (2002) | Gratton et al. (2005) | ||||
---|---|---|---|---|---|---|
Specimens (passed/total) | Inclination range | Paleointensity estimate | Specimens (passed/total) | Curie temp | Paleointensity estimate | |
107 | 0/1 | 3/4 | 580 | 15.3 ± 1.0 | ||
118 | 2/2 | −0.6°–7° | 21.4 ± 1.2 | 0/3 | 570 | |
120 | 2/3 | −2.3°–7.9° | 37.5 ± 3.3 | 0/4 | 515 | |
123 | 1/2 | −7.4°–2.2° | 19.5 | 2/2 | 510 | 12.5 ± 1.2 |
147 | 0/1 | 2/2 | 510 | 11.7 ± 1.7 | ||
148 | 3/3 | −2.4°–0.8° | 19.1 ± 1.6 | 1/2 | 520 | 12.7 |
157 | 2/2 | −12.9° to −0.1° | 27.3 ± 1.4 | 3/3 | 550 | 12.6 ± 1.3 |
191 | 0/3 | 1/2 | 536 | 10.8 | ||
209 | 0/1 | 27.7° | 0/3 | 540 | ||
215 | 1/2 | 580 | 35.7 | |||
224 | 0/1 | 4/4 | 560 | 20.3 ± 3.5 | ||
225 | 0/2 | −3.0°–5.4° | 2/3 | 580 | 10.8 ± 6.8 | |
226 | 2/3 | −7.1° to −3.0° | 22.2 ± 4.5 | 3/3 | 580 | 16.3 ± 1.2 |
228 | 0/1 | 3/3 | 540 | 11.0 ± 1.6 | ||
232 | 2/2 | 520 | 13.5 ± 0.2 |