Skip to main content

Table 1 Origin time, hypocenter location, stress drop, its standard error of a target earthquake (TEQ), origin time, and hypocenter location of an empirical Green’s function (EGF) earthquake. ∆σP, ∆σS, and ∆σAVE represent the static stress drop of TEQ for P-, S-, and P- and S-wave analyses, respectively

From: Relationship between coseismic slip and static stress drop of similar aftershocks of the 2007 Noto Hanto earthquake

TEQ ∆σP (MPa) ∆σS (MPa)   EGF earthquake
Origin time (JST) Latitude (°N) Longitude (°E) Along strike (km) Along dip (km) Depth (km) ML    Origin time (JST) Latitude (°N) Longitude (°E) Depth (km) ML
2007/3/31 5:36:16.65 37.20948 136.69727 8.658 14.594 9.196 2.6 2.5 ± 0.5 8.5 ± 1.1 5.7 ± 1.1 2007/3/26 12:18:4.20 37.20960 136.69689 9.196 2.4
2007/3/28 21:14:11.37 37.23408 136.69816 10.185 10.024 5.887 3.0 14.0 ± 1.6 32.2 ± 5.0 19.0 ± 3.0 2007/3/27 16:37:22.98 37.23429 136.69809 5.921 2.3
2007/3/28 1:46:23.32 37.27190 136.72179 14.204 5.153 3.745 2.6   5.2 ± 1.4 a5.2 ± 1.4 2007/3/28 1:53:58.79 37.27194 136.72222 3.730 2.0
2007/3/31 20:32:15.43 37.18780 136.59765 −0.146 9.350 2.943 2.7 3.2 ± 0.2 7.4 ± 0.9 5.0 ± 0.5 2007/3/31 19:36:57.21 37.18740 136.59716 2.923 2.0
2007/4/2 14:33:6.91 37.24506 136.74652 14.445 12.420 8.381 2.8 8.4 ± 0.9 7.8 ± 1.7 8.1 ± 0.9 2007/4/3 4:20:36.55 37.24564 136.74648 8.413 2.1
2007/4/14 9:41:7.99 37.23563 136.65932 7.320 6.164 2.865 2.7 5.6 ± 0.7 13.3 ± 3.0 9.8 ± 1.9 2007/4/12 0:19:0.86 37.23506 136.65905 2.859 2.1
  1. aIndicates that ∆σAVE is equal to ∆σS, because of no estimation of P-wave