Table 2 Hydrothermal flux and permeability of PCB in each run

From: Contention between supply of hydrothermal fluid and conduit obstruction: inferences from numerical simulations

Run Hydrothermal flux (kg s−1) Permeability of PCB (m2)
Initial condition 1000 1.0 × 10−10
1 1000 1.0 × 10−11
2 1000 1.0 × 10−12
3 1000 5.0 × 10−13
4 1000 1.0 × 10−13
5 1500 1.0 × 10−10
6 1500 1.0 × 10−11
7 1500 1.0 × 10−12
8 1500 5.0 × 10−13
9 1500 1.0 × 10−13
10 2000 1.0 × 10−10
11 2000 1.0 × 10−11
12 2000 1.0 × 10−12
13 2000 5.0 × 10−13
14 2000 1.0 × 10−13