Skip to main content

Table 1 Modeling results

From: Shallow hydrothermal reservoir inferred from post-eruptive deflation at Ontake Volcano as revealed by PALSAR-2 InSAR

 

Crack

Mogi

FEM

Depth (m)

690

390

500

Deflation volume (m3)

3.6 × 105

2.9 × 105

3.5 × 105

Residuala

1.80

1.39

0.84

  1. aResidual is defined as \(\sqrt[{}]{{\frac{1}{n}\mathop \sum \limits_{i = 1}^{n} \left( {\frac{{O_{i} - C_{i} }}{{E_{i} }}} \right)^{2} }}\) where Oi, Ci, and Ei are the observed values, calculated values, and observed error values (Fig. 4d–f) at the ith pixel and n is the total number of pixels, respectively