Fig. 8From: Development of miniaturized pick-up amplification circuit for plasma particle detectors on board satellitesMeasured response of the comparator. Waveforms were measured at the monitoring points (see Fig. 6). a Input pulse measured at CHIP IN and b output waveform measured at COMPARATOR OUT. The time axis is defined so that the peak timing of the input waves is at 0 s. Each waveform in panel b corresponds to the waveform of the same color in panel a. In the threshold voltage range of LVTTL, the rising timing difference of the comparator output waveforms fluctuates by up to \(1.2\,\mathrm{ ns}\)Back to article page