Table 1 Summary of the infrasound sources

From: Experiment to distinguish two fumaroles consistently emanating infrasound at Kirishima Iwo-Yama

 

ISC fumarole

IWC fumarole

Noise

Distance from the array (m)

150

300

Distance from the SI microphone (m)

450

15

Peak value of the array CC

0.80

Peak value of the SI-array CC

0.13

0.01

Monopole source amplitude (at 1 m) (Pa)

3

0.2

RMS amplitude at the array (Pa)

0.0200

0.0007

0.0223

RMS amplitude at the SI microphone (Pa)

0.0067

0.0140

0.0257

Power fractions at the array (%)

44.4

0.1

55.5

Power fractions at the SI microphone (%)

5.0

21.8

73.2